TOHATSU BFT250A Service Manual page 183

Hide thumbs Also See for BFT250A:
Table of Contents

Advertisement

dummyhead
dummyhead
2. EMT sensor 1 signal /GND line open circuit
inspection
Turn the combination switch OFF and disconnect
the EMT sensor 1 2P connector
Turn the combination switch ON.
Measure the voltage between the EMT sensor 1 2P
connector
Black) terminal and No.2 (Green) terminal.
Is the measurement within 4.75 – 5.25 V?
YES
NO
MIL BLINKS 25 TIMES (2 LONG BLINKS AND 5 SHORT BLINK) EMT SENSOR
2
ECM
5 V
TOH2
SG2
1. Symptom reproduction test
Turn the combination switch OFF.
Disconnect the EMT sensor 2 2P connector
ECM connector A
joint connector 1
Reset the ECM (page 5-6).
Turn the combination switch ON and check the
number of blinks of the MIL.
Does the MIL blink 25 times?
YES
NO
main wire harness side No.1 (Red/
– Replace the EMT sensor 1 with a new one
and recheck.
– Repair open in the Red/Black or Green
wire harness between the ECM and EMT
sensor 1. If the main wire harness is
correct, replace the ECM with a new one
and recheck.
R
G
JOINT CONNECTOR 1
, ECM connector B
and then reconnect them.
– GO TO STEP 2.
– Temporary
failure
(code
reappear).
.
EMT SENSOR 1 2P CONNECTOR
MAIN WIRE HARNESS SIDE
3
1
,
,
does
not
FUEL SYSTEM
SG2
TOH1
(Green)
(Red/Black)
EMT SENSOR 2
R
G
Bl: Black
Br: Brown
Y: Yellow
O: Orange
Bu: Blue
Lb: Light blue
G: Green
Lg: Light green
R: Red
P: Pink
W: White
Gr: Gray
5-61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents