TOHATSU BFT250A Service Manual page 184

Hide thumbs Also See for BFT250A:
Table of Contents

Advertisement

dummyhead
dummyhead
FUEL SYSTEM
2. EMT sensor 2 signal /GND line open circuit
inspection
Turn the combination switch OFF and disconnect
the EMT sensor 2 2P connector
Turn the combination switch ON.
Measure the voltage between the EMT sensor 2 2P
connector
terminal and No.2 (Green) terminal.
Is the measurement within 4.75 – 5.25 V?
YES
NO
MIL BLINKS 26 TIMES (2 LONG BLINKS AND 6 SHORT BLINKS) EOP SWITCH
(HIGH PRESSURE SIDE)
ECM
12 V
SG2
OPSH
1. Symptom reproduction test
Turn the combination switch OFF.
Disconnect the EOP switch (High pressure side) 2P
connector
wire 6P connector
and then reconnect them.
Reset the ECM (page 5-6).
Turn the combination switch ON and check the
number of blinks of the MIL.
Does the MIL blink 26 times?
YES
NO
5-62
main wire harness side No.1 (Red)
– Replace the EMT sensor 2 with a new one
and recheck.
– Repair open in the Red or Green wire
harness between the ECM and EMT
sensor 2. If the main wire harness is
correct, replace the ECM with a new one
and recheck.
JOINT CONNECTOR 1
3
6
G
G
Y/R
Y/R
, ECM connector B
, joint connector 1
– GO TO STEP 2.
– Temporary
failure
(code
reappear).
.
EMT SENSOR 2 2P CONNECTOR
MAIN WIRE HARNESS SIDE
SG2
(Green)
G/R
Y/R
, switch
does
not
TOH2
(Red)
EOP
SWITCH (HIGH)
G/R
Y/R
Bl: Black
Br: Brown
Y: Yellow
O: Orange
Bu: Blue
Lb: Light blue
G: Green
Lg: Light green
R: Red
P: Pink
W: White
Gr: Gray

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents