TOHATSU BFT250A Service Manual page 51

Hide thumbs Also See for BFT250A:
Table of Contents

Advertisement

dummyhead
dummyhead
THERMOSTAT COVER
TUBE CLAMP D29.0
(Install the clamp end gap
facing the horizontal direction.)
TUBE CLIP B12.5
L. WATER RELIEF TUBE
Install the longer side of the
water relief tube into the
thermostat. Install the shorter
side of the water relief tube
into the exhaust manifold.
The tubes have a paint mark
for the installation direction.
The relief tube should be
installed so that the paint mark
is on the exhaust manifold.
TUBE CLIP B12.5
77 mm (3.0 in)
THERMOSTAT
SIDE
TUBE CLAMP 65
FLUSH VALVE TUBE
SERVICE INFORMATION
55 mm
(2.2 in)
EXHAUST MANIFOLD SIDE
TUBE CLAMP D29.0
L. EXHAUST
MANIFOLD
TUBE CLAMP
D10.5
L. WATER
RETURN TUBE
TUBE CLAMP D10.5
TUBE CLAMP D21.0
L. WATER TUBE
2-35