Operation
• UTXDn is held marking
• The receiver is clocked by the transmitter clock. The transmitter must be enabled,
but the receiver need not be.
23.5.3.3 Remote Loop-Back Mode
In remote loop-back mode, shown in Figure 23-24, the channel automatically transmits
received data bit by bit on the UTXDn output. The local CPU-to-transmitter link is
disabled. This mode is useful in testing receiver and transmitter operation of a remote
channel. For this mode, the transmitter uses the receiver clock.
Because the receiver is not active, received data cannot be read by the CPU and all status
conditions are inactive. Received parity is not checked and is not recalculated for
transmission. Stop bits are sent as they are received. A received break is echoed as received
until the next valid start bit is detected.

23.5.4 Multidrop Mode

Setting UMR1n[PM] programs the UART to operate in a wake-up mode for multidrop or
multiprocessor applications. In this mode, a master can transmit an address character
followed by a block of data characters targeted for one of up to 256 slave stations.
Although slave stations have their channel receivers disabled, they continuously monitor
the master's data stream. When the master sends an address character, the slave receiver
channel notifies its respective CPU by setting USRn[RxRDY] and generating an interrupt
(if programmed to do so). Each slave station CPU then compares the received address to its
station address and enables its receiver if it wishes to receive the subsequent data characters
or block of data from the master station. Slave stations not addressed continue monitoring
the data stream. Data fields in the data stream are separated by an address character. After
a slave receives a block of data, its CPU disables the receiver and repeats the process.
Functional timing information for multidrop mode is shown in Figure 23-25.
23-26
Disabled
Rx
CPU
Disabled
Tx
Figure 23-24. Remote Loop-Back
MCF5282 User's Manual
Disabled
URXDn Input
Disabled
UTXDn Input
MOTOROLA