Commissioning and diagnostics using the web server
6.6 System settings in the web server
6.6.2

Updating the firmware via the web server

Carefully ensure that when upgrading, the converter settings are kept. For a downgrade, the
converter is reset to the factory settings.
You can find the firmware versions available at the following link:
Firmware versions (https://support.industry.siemens.com/cs/ww/en/view/109744577)
Requirements
You have saved the zip file with the firmware to a drive, which you can access using the
commissioning device.
The firmware can be updated from version 5.2 and higher.
Procedure
1. Select "System > Firmware update" in the navigation.
2. Select the zip file with the firmware version that you wish to load to the converter
3. Start the firmware update.
4. The new firmware is installed – this can take up to five minutes or longer. The update is
completed when both LEDs are flashing red at 1 Hz in sync with each other.
246
RDY
COM
Explanation of the LED displays
Firmware update is active
● Do not switch off the power supply.
● Do not disconnect the motor from the converter.
LEDs are flashing synchronously:
Converter waits until the power supply is switched off and switched on again
after a firmware update.