Label
Pr3.14
Range
Activation
To set sigmoid acceleration and deceleration turning point in accordance to Pr3.12 and Pr3.13.
Velocity
(RPM)
Target
velocity
Vc
Label
Pr3.15
Range
Activation
Set
value
0
Invalid: zero speed clamp deactivated
Velocity command is forced to 0 when the zero speed clamp (ZEROSPD) input
1
signal is valid.
2
Velocity command is forced to 0 when actual velocity is lower than Pr3.16.
3
Includes conditions from 1 and 2
Label
Range
Pr3.16
Activation
Velocity command is forced to 0 when actual velocity is lower than Pr3.16 and after static time set
in Pr3.23
Sigmoid
acceleration/deceleration
settings
0~1000
Unit
Axis disable
ts
ta=Vc/1000 PA3.12 1ms
td=Vc/1000 PA3.13 1ms
ts=Pr3.14 1ms
ts
Please set according to
ta/2>ts、td/2>ts
ta
Zero speed clamp function
selection
0~3
Unit
Immediate
Zero speed clamp level
10~2000
Unit
Immediate
User manual of EL8-EC***F AC Servo
Mode
ms
Default
ts
ts
Time
td
Mode
-
Default
Zero speed clamp function
Mode
Default
RPM
PV
0
Index
0
Index
PV
30
Index
95
CS
V
2314h
F
2315h
CSV
2316h