Definition of bit 8 and bit 13~12 in different operation modes are shown in the following
table
Bit
Profile
Profile
Position
Velocity
(PP)
Position
13
error is too
large
Velocity
12
-
Abnormal
8
stop

5.4.9 Synchronous cycle time setting

The default synchronous cycle time range of EL8-EC series is 250us – 10ms. Min value:
125us; Max value: 20ms. Please make sure the values set is the multiplier of 250us.

5.4.10 Driver Enabling

This section describes how to use control words 6040h/ status word 6041h command
switching/status determination forEL8-EC controlled motor.
Steps:
1:
Write 0 to the control word 6040h, and then AND 0x250 by bit, whether it is equal to 0x250
2:Write 6 to the control word 6040h, and then AND 0x231 by bit, whether it is equal to 0x231
3:Write 7 to the control word 6040h, and then AND 0x233 by bit, whether it is equal to 0x233
4:Write 15 to the control word 6040h, and then AND 0x237 by bit, whether it is equal to 0x237
Operation Mode
Profile
Torque
(PV)
(PT)
-
-
-
is 0
completed
Abnormal
-
-
User manual of EL8-EC***F AC Servo
Cyclic
Homing
Sync
(HM)
Position
(CSP)
Homing
Process
-
error
Homing
Following
Process
valid
Abnormal
stop
stop
Cyclic
Cyclic
Sync
Sync
Velocity
Torque
(CSV)
(CST)
-
-
Following
Following
valid
valid
-
-