4.4 Panel Display and Operation

4.4.1 Panel Operation

Power on
rEAdy
Display
for 1s
S
0
S
Initialization display
Parameter setting
Select
needed
value
rEAdY
(1)
will be displayed for about 1 second after driver is powered on. Then,
automatically enters data monitoring mode and displays initial data value. Otherwise,
alarm code will be displayed if error occurs.
(2) Press M key to switch between modes.
Data monitoring mode → Parameters setting mode → Auxiliary functions mode
Alarm code will be displayed regardless of any mode if alarm occurs. Press M to switch to
other modes.
(3) Press
or
to select the type of parameters in data monitoring mode. Press S to
confirm.
(4) Press
to select current segment in parameters settings mode. Press
increase/decrease the value of segment. Press S to confirm the modified value(s) and
save the parameters.
Data monitoring
mode
D00 uE
D35 SF
M
PA 0001
PA 0000
P A 0 0 0 0
PA 0095
P A 9 0 0 0
M
A F InI
辅助功能模式
AF V o g
A F r s t
Flow diagram of panel operation
User manual of EL8-EC***F AC Servo
D01 SP
S
M
r
0
S
Display monitoring data
0
S
Parameter
value
Vog -
Trial run
S r U o n
p
Trial run
velocity
or
to
Modify
parameter
400