2 :Motor decelerates and stops through 6085h. Status: Switch on disable, axis disabled.
3 :Motor decelerates and stops through 60C6h. Status: Switch on disable, axis disabled.
5 :Motor decelerates and stops through 6084h. Status: Quick stop
6 :Motor decelerates and stops through 6085h. Status: Quick stop
7 :Motor decelerates and stops through 60C6h. Status: Quick stop
HM
0 :To stop motor through Pr5.06. Status: Switch on disable, axis disabled.
1 :Motor decelerates and stops through 609Ah. Status: Switch on disable, axis disabled.
2 :Motor decelerates and stops through 6085h. Status: Switch on disable, axis disabled.
3 :Motor decelerates and stops through 60C6h. Status: Switch on disable, axis disabled.
5 :Motor decelerates and stops through 609Ah. Status: Quick stop
6 :Motor decelerates and stops through 6085h. Status: Quick stop
7 :Motor decelerates and stops through 60C6h. Status: Quick stop
CST
0 :To stop motor through Pr5.06. Status: Switch on disable, axis disabled.
1, 2 :Motor decelerates and stops through 6087h. Status: Switch on disable, axis disabled.
3 :Motor decelerates and stops through torque = 0. Status: Switch on disable, axis disabled.
5, 6 :Motor decelerates and stops through 6087h. Status: Quick stop
7 :Motor decelerates and stops through torque = 0. Status: Quick stop
Label
Index
605Bh
Range
PP, CSP, CSV, PV
0 :To stop motor through Pr5.06, Pr5.06 = 0(Emergency stop), Pr5.06=1(Free stop)
1 :Motor decelerates and stops through 6084h
HM
0 :To stop motor through Pr5.06, Pr5.06 = 0(Emergency stop), Pr5.06=1(Free stop)
1 :Motor decelerates and stops through 609Ah
CST
0 :To stop motor through Pr5.06, Pr5.06 = 0(Emergency stop), Pr5.06=1(Free stop)
1 :Motor decelerates and stops through 6087h
Label
Index
605Ch
Range
PP, CSP, CSV, PV
0 :To stop motor through Pr5.06, Pr5.06 = 0(Emergency stop), Pr5.06=1(Free stop)
1 :Motor decelerates and stops through 6084h
HM
0 :To stop motor through Pr5.06, Pr5.06 = 0(Emergency stop), Pr5.06=1(Free stop)
Motor
deceleration-stopping
mode selection
RW
Unit
Axis disabled-stopping mode
selection
RW
Unit
User manual of EL8-EC***F AC Servo
Mode
-
Range
0~1
Mode
-
Range
0~1
Default
0
Default
0