Z-Signal
HOMING SWITCH
Positive limit
POT
A:
HOMING SWITCH=OFF
POT=OFF
B:
HOMING SWITCH=ON
POT=OFF
C:
HOMING SWITCH=OFF
POT=OFF
Mode 9
Diagram A: Homing switch & positive limit switch = OFF
1. Move in positive direction at high velocity until after homing switch.
2. Move in negative direction at low velocity and stops after homing switch valid and
first encoder Z-signal valid.
Diagram B: Homing switch = ON, positive limit switch = OFF
1. Start to move at homing switch position in positive direction at high velocity until
homing switch invalid.
2. Move in negative direction at low velocity and stops after homing switch valid and
first encoder Z-signal valid
Diagram C: Homing switch & positive limit switch = OFF
1. Move in positive direction at high velocity until positive limit switch valid.
2. Move in negative direction at high velocity until homing switch valid.
3. Move in positive direction at high velocity until after homing switch.
4. Move in negative direction at low velocity and stops after homing switch valid and
first encoder Z signal valid
If the negative limit switch signal is valid during the homing process, the status word
(6041h) bit 13 will be valid, indicating homing error and the motor will stop immediately.
High Velocity
Stop
6099h-01h
8
8
8
User manual of EL8-EC***F AC Servo
Low Velocity
6099h-02h
205