2.16.6 Digital Input Signal Settings

CN1 PIN
Signal
6
DI-COM
5
7
8
9
10
11
12
13
When limit switch or emergency stop is used, POT, NOT and E-STOP signal will be
normally close (NC) by default. Please make sure there is no safety concern if these
signals need to be set to normally open (NO).
Servo drive power on signal (SRV-ON) is set as normally open (NO) as default.
Please make sure there is no safety concern if this signal needs to be set to normally
close (NC).
If a same function is assigned to multiple pins, Er210 might occur.

2.16.7 Digital Output Signal Settings

CN1
1
2
25
26
3
4
Digital output functions can be assigned to multiple pins at the same time.
Parameter
-
DI1
Pr4.00
DI2
Pr4.01
DI3
Pr4.02
DI4
Pr4.03
DI5
Pr4.04
DI6
Pr4.05
DI7
Pr4.06
DI8
Pr4.07
Signal
Parameter
DO1+
Pr4.10
DO1-
DO2+
Pr4.11
DO2-
DO3+
Pr4.12
DO3-
User manual of EL8-EC***F AC Servo
Default function
Common DI
-
POT
NOT
HOME-SWITCH
-
-
-
-
Function
External break released
BRK-OFF
Servo Ready
S-RDY
Servo Alarm
(ALARM)
Default status
-
Normally open
Normally open
Normally open
Normally open
Normally open
Normally open
Normally open
Normally open
54