Holding Brake Wiring Diagram - Leadshine EL8-EC Series User Manual

Ac servo drive
Table of Contents

Advertisement

2.7.1 Holding brake wiring diagram

Holding brake is activated when servo drive is not powered on to prevent axis from
moving due to gravitational pull or other external forces by locking the motor in place.
Usually used on axis mounted vertically to the ground so that the load would not drop
under gravitational force when the driver is powered off or when alarm occurs.
EL8 series servo drives support direct drive holding brake. Please connect BR+ and BR-
to an external 24v power supply and motor brake terminal to control the holding brake.
There is no need for an external relay.
1. Using internal holding brake output port X3 (Easy wiring, no need for an extra relay)
Single Phase
220VAC
2.Connect to the DO(BRW+/BRW-)
Single Phase
220VAC
User manual of EL8-EC***F AC Servo
Servo drive
L1C
U
V
L2C
W
PE
L1
L2
CN2
BR+
BR-
Servo Drive
L1C
U
L2C
V
W
L1
PE
L2
CN1
DO1+(BRK-OFF+)
DO1-(BRK-OFF-)
DC 24V
CN2
P
SG
External 24V
Brake 24V
EN
Brake 0V
M
Brake Relay
BK-RY
B
K
24VDC brake power
supply
PG
32
Motor
Encoder
Holding
brake
Motor
Holding
brake
Encoder

Advertisement

Table of Contents
loading

This manual is also suitable for:

El8-ec400El8-ec750El8-ec1000