Leadshine EL8-EC Series User Manual page 312

Ac servo drive
Table of Contents

Advertisement

Main
Sub
Error
code
0E
Cause
Driver power output
short circuit
Motor wiring error
IGBT module short
circuit
IGBT module
undervoltage
Control parameter
anomaly
Control command
anomaly
Main
Sub
Error
code
0E
Cause
Driver U, V, W terminals
shorted to ground
Motor shorted to ground
Main
Sub
Error
code
0E
Cause
Driver U, V, W terminals
shorted to ground
Motor shorted to ground
Display:
"Er
0E1"
1
Content: Intelligent Power Module (IPM) overcurrent
Diagnosis
Verify if there is short circuit
between UVW terminals, or
shorted to PG.
Verify motor wiring
Disconnect motor output cable.
Then, enable servo driver to
check for overcurrent
Verify if parameter exceeds
recommended range
Verify if command motion is too
acute
Display:
"Er
0E2"
2
Content: Power output to motor shorted to ground
Diagnosis
Disconnect motor power cable
and check for short circuit
between driver UVW and PE
Connect motor power cable to
driver power output. Verify if
resistance value of UVW to PE is
in the range of MegaOhm (MΩ)
Display:
"Er
0E4"
2
Content: Phase overcurrent
Diagnosis
Disconnect motor power cable
and check for short circuit
between driver UVW and PE
Connect motor power cable to
driver power output. Verify if
resistance value of UVW to PE is
equal and if there is short circuit
User manual of EL8-EC***F AC Servo
Solution
1. Make sure there is no circuit.
2. Make sure motor is not
damaged
Reconnect motor wiring
Replace driver
/
Replace driver
Set parameter within
recommended range.
Modify control command;
use filter
Solution
1. Reconnect wiring.
2. Change motor power cable.
Replace motor
Solution
1. Reconnect wiring.
2. Change motor power cable.
Replace motor
312

Advertisement

Table of Contents
loading

This manual is also suitable for:

El8-ec400El8-ec750El8-ec1000

Table of Contents