Leadshine EL8-EC Series User Manual page 334

Ac servo drive
Table of Contents

Advertisement

Sub
Main
Error
code
83
5
Cause
The status of the error
can be detected
Network port LED
The result status
Solution
Main
Sub
Error
code
83
6
Cause
The status of the error
can be detected
Network port LED
The result status
Solution
Main
Sub
Error
code
85
0
Cause
The status of the error
can be detected
Network port LED
The result status
Solution
Main
Sub
Error
code
85
1
Cause
The status of the error
can be detected
Network port LED
The result status
Solution
Display:
"Er
835"
Error description: Distribution Clock cycle time is invalid
Set synchronization cycle time is not proportional to drive position loop
Safe operation
Flickering
Pre-operation
Refer to user manual to set a reasonable synchronization cycle time.
Display:
"Er
836"
Error description: Invalid Distribution Clock synchronization cycle time
The synchronization cycle time setting is not as the following
1:125us 2:250us 3:500us
4:750us 5:1000us 6:2000us
7:4000us
Safe operation
Single flash
Pre-operation
Verify master device synchronization cycle time
Display:
"Er
850"
Error description: EEPROM is inaccessible
EtherCAT slave controller failed to access EEPROM
All ESM status
Flickering
Keeping the current state
1. Verify if EL8-EC hardware is faulty
2. Verify if master device released access
Display:
"Er
851"
Error description: EEPROM error
EEPROM operation of EtherCAT slave controller failed
All ESM status
Flickering
Keeping the current state
Verify if master device released access
User manual of EL8-EC***F AC Servo