Leadshine EL8-EC Series User Manual page 204

Ac servo drive
Table of Contents

Advertisement

Start
Z-Signal
HOMING SWITCH
Positive limit
POT
A:
HOMING SWITCH=OFF
POT=OFF
B:
HOMING SWITCH=ON
POT=OFF
C:
HOMING SWITCH=OFF
POT=OFF
Mode 8
Diagram A: Homing switch & positive limit switch = OFF
1. Move in positive direction at high velocity until homing switch valid.
2. Move in negative direction at high velocity until after homing switch.
3. Move in positive direction at low velocity and stops after homing switch valid and
first encoder Z-signal valid.
Diagram B: Homing switch = ON, positive limit switch = OFF
1. Start to move at homing switch position in negative direction at high velocity until
after homing switch.
2. Move in positive direction at low velocity and stops after homing switch valid and
first encoder Z-signal valid
Diagram C: Homing switch & positive limit switch = OFF
1. Move in positive direction at high velocity until positive limit switch valid.
2. Move in negative direction at high velocity until after homing switch.
3. Move in positive direction at low velocity and stops after homing switch valid and
first encoder Z-signal valid.
If the negative limit switch signal is valid during the homing process, the status word
(6041h) bit 13 will be valid, indicating homing error and the motor will stop immediately.
High velocity
Stop
6099h-01h
7
7
7
User manual of EL8-EC***F AC Servo
Low velocity
6099h-02h
204

Advertisement

Table of Contents
loading

This manual is also suitable for:

El8-ec400El8-ec750El8-ec1000

Table of Contents