Safety Functions; External Brake Deactivation Output Signal Brk-Off - Leadshine EL8-EC Series User Manual

Ac servo drive
Table of Contents

Advertisement

(2)Continuous trigger mode
The data saved from signal triggering will be saved until the next trigger signal.
Enabling the probe again is not needed. Sequence diagram as shown below:

6.18 Safety Functions

6.18.1 External brake deactivation output signal BRW-OFF
Please refer to Pr4.11 to set up the I/O output function parameters. When enabled and
timing conditions are fulfilled, the set I/O output will deliver ON signal.
Name
Range
Pr4.37
Activation
To set delay time for holding brake to be activated after motor power off to prevent axis from
sliding.
Name
Pr4.38
Range
Activation
To set delay time for holding brake to be released after motor power on. Motor will
remain at current position and input command is masked to allow holding brake to be
fully released before motor is set in motion.
Motor power-off delay time
0~3000
Unit
Immediate
Delay time for holding brake
release
0~3000
Unit
Immediate
User manual of EL8-EC***F AC Servo
Mode
1ms
Default
100
Mode
1ms
Default
0
Index
2437h
Index
2438h
281
F
F

Advertisement

Table of Contents
loading

This manual is also suitable for:

El8-ec400El8-ec750El8-ec1000

Table of Contents