6. d09Cn Control mode
D09 Cn
7. d10Io I/O signal status
When the top half of the digital tube is lighted, the signal is valid; when the bottom half
of the digital tube is lighted, the signal is not valid. Decimal points represent I/O status,
input when lighted, output when not lighted.
■ Input:
From low to high bit(Right to left) DI1,DI2....DI10. Decimal point is lighted to
represent input signals.
In the example below, DI1, DI8 and DI10 input signal is valid; DI2-DI7, DI9
input signal is invalid.
■
Output:From low to high bit(Right to left) DO1,DO2....DO10. Decimal point is not
lighted to represent output signals.
In the example below, DO1 output signal is valid; DO2-DO10 output signal is
invalid.
Ct pos
S
Ct spd
Ct trq
User manual of EL8-EC***F AC Servo
Position control mode
Velocity control mode
Torque control mode
165