8.3 Alarm Handling

**When error occurs, please solve accordingly. Then, restart. If the solutions described
don't work, please consider replacing the driver.
Main
Sub
Error
code
09
0~F
Cause
L1, L2 terminal voltage too
low
Main
Sub
Error
code
0A
0~1
Cause
Motor power cable wiring
error
Main power supply
undervoltage
Main
Sub
Error
code
0A
2 / 4
Cause
Analog input wiring error
Main
Sub
Error
code
0A
Cause
Motor power cable not
connected
Motor fault
Display:
"Er 090"--"Er
Content: FPGA communication error
Diagnosis
Verify L1, L2 terminal
voltage
Display:
"Er 0A0"--"Er
Content: Circuit current detection error
Diagnosis
Verify motor power cable
wiring
Verify
L1,L2,L3
voltage
Display:
"Er
Content: Analog input error
Diagnosis
Verify analog input wiring
Display:
"Er
3
Content: Motor power cable not connected
Diagnosis
Verify motor power cable
wiring
User manual of EL8-EC***F AC Servo
09F"
Solution
Make sure L1, L2 terminal voltage is
within recommended range
0A1"
Solution
Make sure U,V,W terminal wired
properly
terminal
Increase main power supply voltage
0A2" /
"Er
0A4"
Solution
Make sure of analog input wiring
connection
0A3"
Solution
Measure resistance values
between U, V, W terminals, make
sure the values are almost equal. If
not, might be due to damaged motor
or motor winding open circuit.
/
Replace motor