1 :Motor decelerates and stops through 609Ah
CST
0 :To stop motor through Pr5.06, Pr5.06 = 0(Emergency stop), Pr5.06=1(Free stop)
1 :Motor decelerates and stops through 6087h
Label
Index
605Dh
Access
When control word – pause sets decelerating, stopping mode. Also suitable for deceleration mode
settings during mode switching
PP, CSP, CSV, PV
1 :Motor decelerates and stops through 6084h. Status: Operation enabled, axis enabled.
2 :Motor decelerates and stops through 6085h. Status: Operation enabled, axis enabled.
3 :Motor decelerates and stops through 60C6h. Status: Operation enabled, axis enabled.
HM
1 :Motor decelerates and stops through 609Ah. Status: Operation enabled, axis enabled.
2 :Motor decelerates and stops through 6085h. Status: Operation enabled, axis enabled.
3 :Motor decelerates and stops through 60C6h. Status: Operation enabled, axis enabled.
CST
1, 2 :Motor decelerates and stops through 6087h. Status: Operation enabled, axis enabled.
3 :Motor decelerates and stops through torque = 0. Status: Operation enabled, axis enabled.
Alarm - stopping mode
Label
Index
selection
605Eh
RW
Access
Select stopping mode when servo alarm (Err 8xx) occurs.
PP, CSP, CSV, PV
0 :Select motor stopping mode according to alarm properties. Status: Fault, axis disabled.
1 :Motor decelerates and stops through 6084h. Status: Fault, axis disabled.
2 :Motor decelerates and stops through 6085h. Status: Fault, axis disabled.
HM
0 :Select motor stop by the alarm attribute for emergency stop, the fault state and disable
1 :After the 609Ah motor is decelerated and stopped,, the fault state and disable
2 :After the 6085h motor is decelerated and stopped, the fault state and disable
CST
0, 1 :Select motor stop by the alarm attribute for emergency stop, the fault state and disable
2 :After the 6087 motor is decelerated and stopped, the fault state and disable
When other alarms, i.e. drive-side alarms:
Select motor stop by the alarm attribute for emergency stop, the fault state and disable
Pause-stopping
mode
selection
RW
Mapping
-
-
Mapping
User manual of EL8-EC***F AC Servo
Unit
-
Structure
Mode
F
Range
Unit
-
Structure
F
Mode
Range
VAR
INT 16
Type
1~3
Default
1
VAR
Type
INT 16
0~2
0
Default
124