6.18.2 Emergency stop function

Emergency stop is used when an alarm occurs or a servo prohibition signal is received
when servo driver is enabled.
Method 1: Set up Pr4.43 to enable the function
Name
Range
Pr4.43
Activation
0:Emergency stop is valid, servo driver will be forced to STOP and alarm occurs.
1:Emergency stop is invalid, servo driver will not be forced to STOP.
Name
Pr5.04
Range
Activation
To set driver prohibition input (POT/NOT): If set to 1, no effect on homing mode.
Set value
0
1
2
In homing mode, POT/NOT invalid, please set object dictionary 5012-04 bit0=1
Method 2: Using 605Ah object dictionary through master device to activate this function.
Name
Pr5.11
Range
Activation
To set torque limit for servo braking mode.
If Pr5.11 = 0, use torque limit as under normal situation.
Between max. torque 6072 and Pr5.11, actual torque limit will take smaller value.
Emergency stop function
0~1
Unit
Immediate
Driver prohibition input
settings
0~2
Unit
Immediate
POT  Positive direction drive prohibited
NOT  Negative direction drive prohibited
POT and NOT invalid
Any single sided input from POT or NOT might cause Er260
Servo braking torque setting
0~500
Unit
Immediate
User manual of EL8-EC***F AC Servo
Mode
-
Default
Mode
Defaul
0
t
Explanation
Mode
%
Default 0
0
Index
Index
2504h
Index
283
F
2443h
F
F
2511h