AF Vog Trial run
Please disable servo driver before performing any trial run.
Please don't modify gain related parameters during trial run to prevent any
occurrence of mechanical vibrations.
Only use trial run when Pr0.01 set to 0, 1, 6.
Please check Pr6.04 (JOG velocity) and Pr6.25 (JOG acceleration) before running.
Press S to exit trial run.
Auxiliary functions
AF Vog
Trial run
AF Inl Reset to factory default
To reset parameters settings to factory default. Can be used to reset parameters using
auxiliary function on front panel or using object dictionary.
Auxiliary function
AF Vog
Press ▲ to look for AFInI
AF InI
Reset to factory
default
Vog -
S
Press
to enable driver.
Sr Uon will be displayed.
Sr Uon
CCW▲
P 400
When Sr Uon is displayed, press ▲▼ to move
motor in CW or CCW direction.
Hold ▲
to move motor at velocity set in
Pr6.04
I n I -
S
Hold ▲ to reset.
Ar A0E is displayed once completed.
Ar A0E
If driver is enabled
when holding ▲, error
might occur
User manual of EL8-EC***F AC Servo
Operation
Initialization
Error
If driver is
enabled before
▼CW
is pressed, error
might occur.
n 400
Operation
Initialization
E r r o r