Leadshine EL8-EC Series User Manual page 287

Ac servo drive
Table of Contents

Advertisement

Output conditions of INP1 positioning completed output signal
Set value
0
1
2
3
4
Name
Pr4.33
Range
Activation
To set delay time when Pr4.32 = 3
Set value
0
1-15000
Positioning completed signal
Signal valid when the position deviation is smaller than Pr4.31
Signal valid when there is no position command and position deviation is
smaller than Pr4.31
Signal valid when there is no position command, zero-speed clamp
detection (ZSP) signal is ON and the positional deviation is smaller than
Pr4.31
Signal valid when there is no position command and position deviation is
smaller than Pr4.31. Signal ON when within the time set in Pr4.33
otherwise OFF.
When there is no command, position detection starts after the delay time
set in Pr4.33.
Signal valid when there is no position command and positional deviation
is smaller than Pr4.31.
INP positioning delay time Mode
0~15000
Unit
Immediate
Positioning completed signal
Indefinite delay time, signal ON until next position command
OFF within the time set; ON after time set. Switch OFF after receiving
next position command.
User manual of EL8-EC***F AC Servo
PP
1ms
Default
0
H
CSP
M
Index
2433h