Leadshine EL8-EC Series User Manual page 171

Ac servo drive
Table of Contents

Advertisement

Display setting at power on
■ Default
setting for initialization display settings at power on is
required, please set on Pr5.28.
Please refer to Pr5.28 for any display content required on the front panel during
initialization
Name
Range
Pr5.28
Activation
To set content display on front panel of the servo driver at servo driver power on.
Set
value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
LED initial status
0~42
Unit
After restart
Content
value
Position command
deviation
Motor speed
Position command
velocity
Velocity control
command
Actual feedback
torque
Sum of feedback
pulse
Sum of command
pulse
Maximum torque
during motion
/
Control mode
I/O signal status
/
Error cause and
history record
Alarm code
Regenerative load
rate
User manual of EL8-EC***F AC Servo
Mode
Default
Set
Content
15
Overload rate
Inertia ratio
16
No rotation cause
17
No. of changes in
18
I/O signals
Number of over
19
current signals
Absolute encoder
20
data
Single turn
21
position
Multiturn position
22
Communication
23
axis address
Encoder position
24
deviation
Motor electrical
25
angle
Motor mechanical
26
Angle
Voltage across PN
27
Software version
28
/
29
d34
,if any other display is
34
Index
Set
Content
value
No. of encoder
communication
30
error
Accumulated
31
operation time
Automatic motor
32
identification
Driver temperature
33
Servo status
34
35
Synchronous period
36
No. of synchronous
37
loss
Synchronous type
38
Whether DC is
39
running or not
Acceleration/Deceler
40
ation status
Sub-index of OD
41
index
Value of sub-index of
42
OD index
F
2528h
/
171

Advertisement

Table of Contents
loading

This manual is also suitable for:

El8-ec400El8-ec750El8-ec1000

Table of Contents