Class 4】I/O Interface Setting - Leadshine EL8-EC Series User Manual

Ac servo drive
Table of Contents

Advertisement

23
24
25
26~28
29
30
31
Label
Pr3.75~
Range
Pr3.94
Activation
x,y = (3,4), (5,6)........(41,42)
bit 0~15: Position comparison x; bit 16~31: Position comparison y
Please refer to Pr3.74
3.2.5【Class 4】I/O Interface Setting
Label
Range
Pr4.00
Activation
Label
Range
Pr4.01
Activation
Label
Range
Pr4.02
Activation
Label
Range
Pr4.03
Activation
Label
Range
Pr4.04
Activation
Label
Pr4.05
Range
=1:Flipping mode
DO1
DO2
DO3
Reserved
Frequency divider Phase A output
Frequency divider Phase B output
Frequency divider Phase Z output
Position comparison x & y
attributes value
0x0~0xFF
Unit
FFFFFF
Immediate
Input selection DI1
0x0~0xFF
Unit
Immediate
Input selection DI2
0x0~0xFF
Unit
Immediate
Input selection DI3
0x0~0xFF
Unit
Immediate
Input selection DI4
0x0~0xFF
Unit
Immediate
Input selection DI5
0x0~0xFF
Unit
Immediate
Input selection D16
0x0~0xFF
Unit
User manual of EL8-EC***F AC Servo
Mode
Default
0
-
Mode
Default
0x0
Mode
Default
0x1
Mode
Default
0x2
Mode
Default
0x16
Mode
Default
0x0
Mode
Default
0x0
2375h-
Index
2394h
Index
2400h
Index
2401h
Index
2402h
Index
2403h
Index
2404h
Index
2405h
97
F
F
F
F
F
F
F

Advertisement

Table of Contents
loading

This manual is also suitable for:

El8-ec400El8-ec750El8-ec1000

Table of Contents