Leadshine EL8-EC Series User Manual page 177

Ac servo drive
Table of Contents

Advertisement

AF rSt Software reset
Software reset is used mainly on parameters modification that takes effect only after driver
restart.
Auxiliary function
Software
AF rSt
reset
S
Reset completed
AF_tun One click auto tuning
One click auto tuning can be applied by operating the front panel. Set simple movement
range and movement range has to be more than 0.5 motor revolution.
Auxiliary function
One click
AF tUn
Auto tuning
rSt -
S
Hold ▲
start reseting
StArt
0
LED displayed will be off for 3s and back to
initialization page once completed.
tUn ---
S
Press
to enter one click auto tuning.
srUon
will be displayed.
SrUon
CCW▲
P
30
r
t
t 100
FinSh
Press
to get back to SrUon.
Press
again to get back to
initialization page
User manual of EL8-EC***F AC Servo
Operation
Initialization
StArt
will be displayed to
Start to reset
Operation
Initialization
Error
before ◀ is pressed,
If driver is enabled
error might occur
▼CW
SrUon
When
displayed, hold
▲▼ to perform CCW/CW
n
30
motion for a suitable
movement range.
Position will be
showed after motion
5
stops.
After setting movement range,
Hold S
hold S to start tuning.
Shows tuning progress in %.
5
Tuning done at 100. Hold M to
save the parameter. If user does
not want to save, hold
back to SrUon
Hold M
FinSh
will be displayed
after saving completed.
is
to get
177

Advertisement

Table of Contents
loading

This manual is also suitable for:

El8-ec400El8-ec750El8-ec1000

Table of Contents