8.1 Servo drive warning
When warning occurs, driver will set protective function but motor won't stop
moving. Error code will be displayed on the front panel.
Example of warning code:
Warning
Code
Main
Code
1
Overload warning
2
Regeneration energy overload warning(85% of the regeneration threshold)
3
Absolute encoder battery voltage low (<3.1V). Valid when Pr0.15 is set to 1.
4
Change the parameter to a non-real time valid warning
7
Low temperature warning ( < 20℃)
8
Positive limit switch valid. POT blinking on front panel
A0
9
Negative limit switch valid. NOT blinking on front panel
A
Positive and negative limit switch valid. PNOT blinking on front panel
B
Current position is beyond software positive limit. SPOT blinking on front panel
C
Current position is beyond software negative limit. NPOT blinking on front panel
Current position is beyond software negative, positive limit. SPNOT blinking on front
D
panel
E
Parameters reset to factory default. Restart needed
8.2 Servo drive alarm
When alarm occurs, driver will set protective function and motor stops moving.
Error code will be displayed on the front panel. Alarm history record can also be viewed in
data monitoring mode, with the alarm log sub-menu displaying "
Chapter 8 Warning and Alarm
Ar A08
User manual of EL8-EC***F AC Servo
Others
P O T
Bit 1:Sub-code
Bit 2:Main code
Content
d12Er
".