Mode 26:
This mode is similar to mode 10. Only difference is that homing point detection is not
through Z-signal but through triggering of homing switch signal
Start
Z-signal
HOMING SWITCH
Positive limit
POT
A:
HOMING SWITCH=OFF
POT=OFF
B:
HOMING SWITCH=ON
POT=OFF
C:
HOMING SWITCH=OFF
POT=OFF
Mode 27:
This mode is similar to mode 11. Only difference is that homing point detection is not
through Z-signal but through triggering of homing switch signal
Start
Z-Signal
HOMING SWITCH
Negative limit
NOT
A:
HOMING SWITCH=OFF
NOT=OFF
B:
HOMING SWITCH=ON
NOT=OFF
C:
HOMING SWITCH=OFF
NOT=OFF
High Velocity
Stop
6099h-01h
High Velocity
Stop
6099h-01h
User manual of EL8-EC***F AC Servo
Low Velocity
6099h-02h
26
26
26
Low Velocity
6099h-02h
27
27
27
216