Parameters Saving - Leadshine EL8-EC Series User Manual

Ac servo drive
Table of Contents

Advertisement

4.5 Parameters saving

Save using driver's front panel
D00 UE
M
PR 0.000
Select value using
After modifying the selected parameter to desired values, press S to confirm and save the
changes. If the parameter is modified but user does not want to save the changes, press
M to exit without saving. Some parameter modifications will only take effect after the driver
is restarted.
Save using object dictionary
Objects
Types
0x1010-01
ALL parameters
0x1010-02
Communication
parameters
402 parameters
0x1010-03
0x1010-04
Manufacturer's
parameters
Increase/decrease value
using ▲ ▼, press S to select
1
S
the parameters to be
modified
Explanations
Master device can save all parameters to EEPROM using
0x1010-01. When the driver detects 0x1010-01 data from
master device as 0x65766173, driver will save current
parameters to EEPROM. After saving, 1010-01=1.
Master device can save communication parameters to
EEPROM using 0x1010-02. When the driver detects
0x1010-02 data from master device as 0x65766173, driver
will save current parameters to EEPROM. After saving,
1010-02=1.
Master device can save 402 parameters to EEPROM using
0x1010-01. When the driver detects 0x1010-03 data from
master device as 0x65766173, driver will save current
parameters to EEPROM. After saving, 1010-03=1.
Master device can save manufacturer's parameters to
EEPROM using 0x1010-01. When the driver detects
0x1010-01 data from master device as 0x65766173, driver
will save current parameters to EEPROM (including
0x2000 to 0x5FFF parameters and electronic gear ratio
parameters)
User manual of EL8-EC***F AC Servo
172

Advertisement

Table of Contents
loading

This manual is also suitable for:

El8-ec400El8-ec750El8-ec1000

Table of Contents