Input References - ABB ACS880 Firmware Manual

Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name / Range /
Selection
3

Input references

3.1
Panel reference
-100000.00 ...
100000.00
3.2
Panel reference 2
-30000.00 ...
30000.00
3.5
FB A reference 1
-100000.00 ...
100000.00
3.6
FB A reference 2
-100000.00 ...
100000.00
3.7
FB B reference 1
-100000.00 ...
100000.00
3.8
FB B reference 2
-100000.00 ...
100000.00
3.9
EFB reference 1
-30000.00 ...
30000.00
3.10
EFB reference 2
-30000.00 ...
30000.00
3.11
DDCS controller ref
1
-30000.00 ...
30000.00
3.12
DDCS controller ref
2
Description
Values of references received from various sources.
All parameters in this group are read-only unless
otherwise noted.
Local reference given from the control panel or PC tool.
Local control panel or PC tool reference.
Remote reference given from the control panel or PC
tool.
Remote control panel or PC tool reference.
Reference 1 received through fieldbus adapter A.
See also chapter
Fieldbus control through a fieldbus
adapter (page
729).
Reference 1 from fieldbus adapter A.
Reference 2 received through fieldbus adapter A.
Reference 2 from fieldbus adapter A.
Reference 1 received through fieldbus adapter B.
Reference 1 from fieldbus adapter B.
Reference 2 received through fieldbus adapter B.
Reference 2 from fieldbus adapter B.
Scaled reference 1 received through the embedded
fieldbus interface. The scaling is defined by
ref1
type.
Reference 1 received through the embedded fieldbus
interface.
Scaled reference 2 received through the embedded
fieldbus interface. The scaling is defined by
ref2
type.
Reference 2 received through the embedded fieldbus
interface.
Reference 1 received from the external (DDCS)
controller.
The value has been scaled according to parameter
60.60 DDCS controller ref1
See also section
External controller interface (page
Scaled reference 1 received from external controller.
Reference 2 received from the external (DDCS)
controller.
The value has been scaled according to parameter
DDCS controller ref2
type.
58.26 EFB
58.27 EFB
type.
60.61
Parameters 179
Def / Type
FbEq 16b / 32b
0.00 / real32
10 = 1 / 100 = 1
- / real32
10 = 1 / 100 = 1
0.00 / real32
10 = 1 / 100 = 1
0.00 / real32
10 = 1 / 100 = 1
0.00 / real32
10 = 1 / 100 = 1
0.00 / real32
10 = 1 / 100 = 1
- / real32
10 = 1 / 100 = 1
- / real32
10 = 1 / 100 = 1
- / real32
81).
10 = 1 / 100 = 1
- / real32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents