ABB ACS880 Firmware Manual page 314

Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

314 Parameters
No.
Name / Range /
Selection
23.17
Shape time acc 2
0.000 ... 1800.000 s
23.18
Shape time dec 1
0.000 ... 1800.000 s
23.19
Shape time dec 2
0.000 ... 1800.000 s
23.20
Acc time jogging
0.000 ... 1800.000 s
23.21
Dec time jogging
0.000 ... 1800.000 s
23.23
Emergency stop
time
0.000 ... 1800.000 s
23.24
Speed ramp in zero
source
Description
Defines the shape of the acceleration ramp at the end
of the acceleration. See parameter
acc
1.
Ramp shape at end of acceleration.
Defines the shape of the deceleration ramp at the
beginning of the deceleration. See parameter
Shape time acc
1.
Ramp shape at start of deceleration.
Defines the shape of the deceleration ramp at the end
of the deceleration. See parameter
acc
1.
Ramp shape at end of deceleration.
Defines the acceleration time for the jogging function
i.e. the time required for the speed to change from zero
to the speed value defined by parameter
scaling.
See section
Jogging (page
Acceleration time for jogging.
Defines the deceleration time for the jogging function
i.e. the time required for the speed to change from the
speed value defined by parameter
to zero.
See section
Jogging (page
Deceleration time for jogging.
In speed control mode, this parameter defines the
deceleration rate for emergency stop Off3 as the time
it would take for the speed to decrease from the value
of parameter
46.1 Speed
torque control because the drive switches to speed
control on receiving an emergency stop Off3 command.
In frequency control mode, this parameter specifies
the time it would take for the frequency to decrease
from the value of
46.2 Frequency scaling
The emergency stop mode and activation source are
selected by parameters
21.5 Emergency stop source
stop can also be activated through fieldbus.
Note: Emergency stop Off1 uses the standard
deceleration ramp as defined by parameters
23.11...23.19
(speed and torque control) or
(frequency control).
Emergency stop Off3 deceleration time.
Selects a source that forces the speed reference to zero
just before it enters the ramp function.
0 = Force speed reference to zero before the ramp
function
1 = Speed reference continues towards the ramp
function as normal
23.16 Shape time
23.16 Shape time
46.1 Speed
99).
46.1 Speed scaling
99).
scaling. This also applies to
to zero.
21.4 Emergency stop mode
respectively. Emergency
28.71...28.75
Def / Type
FbEq 16b / 32b
0.000 s / real32
10 = 1 s / 1000 = 1 s
0.000 s / real32
23.16
10 = 1 s / 1000 = 1 s
0.000 s / real32
10 = 1 s / 1000 = 1 s
60.000 s / real32
10 = 1 s / 1000 = 1 s
60.000 s / real32
10 = 1 s / 1000 = 1 s
3.000 s / real32
and
10 = 1 s / 1000 = 1 s
Inactive / uint32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents