ABB ACS880 Firmware Manual page 616

Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

616 Parameters
No.
Name / Range /
Selection
Cyclic
Custom
97.10
Signal injection
Disabled
Enabled (5 %)
Enabled (10 %)
Enabled (15 %)
Enabled (20 %)
97.11
TR tuning
25...400 %
97.15
Motor model
temperature
adaptation
Disabled
Estimated
temperature
Measured
temperature 1
Measured
temperature 2
Description
Control performance optimized for cyclic load
applications.
This setting is to be used by ABB-authorized service
personnel only.
Enables signal injection. A high-frequency alternating
signal is injected into the motor at low speeds to
improve the stability of torque control. Signal injection
can be enabled with different amplitude levels.
Note: This is an expert level parameter and should not
be adjusted without appropriate skill.
Note: Use as low a level as possible that gives
satisfactory performance.
Note: Signal injection cannot be applied to
asynchronous motors.
Signal injection disabled.
Signal injection enabled with an amplitude level of 5%.
Signal injection enabled with an amplitude level of 10%.
Signal injection enabled with an amplitude level of 15%.
Signal injection enabled with an amplitude level of 20%.
Rotor time constant tuning.
This parameter can be used to improve torque accuracy
in closed-loop control of an induction motor. Normally,
the motor identification run provides sufficient torque
accuracy, but manual fine-tuning can be applied in
exceptionally demanding applications to achieve
optimal performance.
Note: This is an expert level parameter and should not
be adjusted without appropriate skill.
Rotor time constant tuning.
Selects whether the temperature-dependent
parameters (such as stator or rotor resistance) of the
motor model adapt to actual (measured or estimated)
temperature or not.
See parameter group
35 Motor thermal protection
selection of temperature measurement sources.
Temperature adaptation of motor model disabled.
Estimated temperature
temperature) used for adaptation of motor model.
Measured temperature 1
1) used for adaptation of motor model.
Measured temperature 2
2) used for adaptation of motor model.
(35.1 Motor estimated
(35.2 Measured temperature
(35.3 Measured temperature
Def / Type
FbEq 16b / 32b
2
3
Disabled / uint16
0
1
2
3
4
100 % / real32
1 = 1 % / 100 = 1 %
Disabled / uint16
for
0
1
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents