Fba A Data In - ABB ACS880 Firmware Manual

Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

474 Parameters
No.
Name / Range /
Selection
52

FBA A data in

52.1
FBA A data in1
None
CW 16bit
Ref1 16bit
Ref2 16bit
SW 16bit
Act1 16bit
Act2 16bit
CW 32bit
Ref1 32bit
Ref2 32bit
SW 32bit
Act1 32bit
Act2 32bit
SW2 16bit
Other [value]
...
...
52.12
FBA A data in12
Description
Selection of data to be transferred from drive to
fieldbus controller through fieldbus adapter A.
Note: 32-bit values require two consecutive parameters.
Whenever a 32-bit value is selected in a data parameter,
the next parameter is automatically reserved.
Parameters
52.01...52.12
from the drive to the fieldbus controller through
fieldbus adapter A.
None.
Control Word (16 bits)
Reference REF1 (16 bits)
Reference REF2 (16 bits)
Status Word (16 bits)
Actual value ACT1 (16 bits)
Actual value ACT2 (16 bits)
Control Word (32 bits)
Reference REF1 (32 bits)
Reference REF2 (32 bits)
Status Word (32 bits)
Actual value ACT1 (32 bits)
Actual value ACT2 (32 bits)
Status Word 2 (16 bits)
See
Terms and abbreviations (page
...
See parameter
52.1 FBA A data
select data to be transferred
169).
in1.
Def / Type
FbEq 16b / 32b
None / uint32
0
1
2
3
4
5
6
11
12
13
14
15
16
24
...
None / uint32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents