644 Parameters
No.
Name / Range /
Selection
209
I/O bus fan
identification
209.1
Node 1 fan 1 pulse
freq
0.0 ... 5000.0 Hz
209.2
Node 1 fan 2 pulse
freq
0.0 ... 5000.0 Hz
209.3
Node 1 fan 3 pulse
freq
0.0 ... 5000.0 Hz
209.4
Node 1 fan 4 pulse
freq
0.0 ... 5000.0 Hz
209.5
Node 2 fan 1 pulse
freq
0.0 ... 5000.0 Hz
209.6
Node 2 fan 2 pulse
freq
0.0 ... 5000.0 Hz
209.7
Node 2 fan 3 pulse
freq
0.0 ... 5000.0 Hz
209.8
Node 2 fan 4 pulse
freq
0.0 ... 5000.0 Hz
209.9
Node 3 fan 1 pulse
freq
0.0 ... 5000.0 Hz
209.10
Node 3 fan 2 pulse
freq
0.0 ... 5000.0 Hz
209.11
Node 3 fan 3 pulse
freq
0.0 ... 5000.0 Hz
209.12
Node 3 fan 4 pulse
freq
Description
Distributed I/O bus settings.
This group is only visible with a BCU control unit.
This group contain parameters related to the
distributed I/O bus, which is used with some drives for
monitoring the cooling fans of the cabinet system. For
details, refer to CIO-01 I/O module for distributed I/O
bus control user's manual (3AXD50000126880
[English]).
Displays the result of the identification run for fan 1 of
node 1.
Result of the identification run for fan 1 of node 1.
Displays the result of the identification run for fan 2 of
node 1.
Result of the identification run for fan 1 of node 2.
Displays the result of the identification run for fan 3 of
node 1.
Result of the identification run for fan 3 of node 1.
Displays the result of the identification run for fan 4 of
node 1.
Result of the identification run for fan 4 of node 1.
Displays the result of the identification run for fan 1 of
node 2.
Result of the identification run for fan 1 of node 2.
Displays the result of the identification run for fan 2 of
node 2.
Result of the identification run for fan 2 of node 2.
Displays the result of the identification run for fan 3 of
node 2.
Result of the identification run for fan 3 of node 2.
Displays the result of the identification run for fan 4 of
node 2.
Result of the identification run for fan 4 of node 2.
Displays the result of the identification run for fan 1 of
node 3.
This is the block, where writer describes in more details
how the values of parameters should be interpreted.
Displays the result of the identification run for fan 2 of
node 3.
Result of the identification run for fan 2 of node 3.
Displays the result of the identification run for fan 3 of
node 3.
Result of the identification run for fan 3 of node 3
Displays the result of the identification run for fan 4 of
node 3.
Def / Type
FbEq 16b / 32b
0.0 Hz / real32
1 Hz / 10 Hz
0.0 Hz / real32
1 Hz / 10 Hz
0.0 Hz / real32
1 Hz / 10 Hz
0.0 Hz / real32
1 Hz / 10 Hz
0.0 Hz / real32
1 Hz / 10 Hz
0.0 Hz / real32
1 Hz / 10 Hz
0.0 Hz / real32
1 Hz / 10 Hz
0.0 Hz / real32
1 Hz / 10 Hz
0.0 Hz / real32
1 Hz / 10 Hz
0.0 Hz / real32
1 Hz / 10 Hz
0.0 Hz / real32
1 Hz / 10 Hz
0.0 Hz / real32