b3
Follower 20
b4
Follower 21
b5
Follower 22
b6
Follower 23
b7
Follower 24
b8
Follower 25
b9
Follower 26
b10
Follower 27
b11
Follower 28
b12
Follower 29
b13
Follower 30
b14
Follower 31
b15
Follower 32
0000h...FFFFh
60.31
M/F wake up delay
0.0 ... 180.0 s
Description
0 = Status of follower 20 is monitored continuously.
1 = Status of follower 20 is monitored only when it is
in stopped state.
0 = Status of follower 21 is monitored continuously.
1 = Status of follower 21 is monitored only when it is in
stopped state.
0 = Status of follower 22 is monitored continuously.
1 = Status of follower 22 is monitored only when it is in
stopped state.
0 = Status of follower 23 is monitored continuously.
1 = Status of follower 23 is monitored only when it is in
stopped state.
0 = Status of follower 24 is monitored continuously.
1 = Status of follower 24 is monitored only when it is in
stopped state.
0 = Status of follower 25 is monitored continuously.
1 = Status of follower 25 is monitored only when it is in
stopped state.
0 = Status of follower 26 is monitored continuously.
1 = Status of follower 26 is monitored only when it is in
stopped state.
0 = Status of follower 27 is monitored continuously.
1 = Status of follower 27 is monitored only when it is in
stopped state.
0 = Status of follower 28 is monitored continuously.
1 = Status of follower 28 is monitored only when it is in
stopped state.
0 = Status of follower 29 is monitored continuously.
1 = Status of follower 29 is monitored only when it is in
stopped state.
0 = Status of follower 30 is monitored continuously.
1 = Status of follower 30 is monitored only when it is
in stopped state.
0 = Status of follower 31 is monitored continuously.
1 = Status of follower 31 is monitored only when it is in
stopped state.
0 = Status of follower 32 is monitored continuously.
1 = Status of follower 32 is monitored only when it is in
stopped state.
Defines a wake-up delay during which no
master/follower communication faults or warnings are
generated. This is to allow all drives on the
master/follower link to power up.
The master cannot be started until the delay elapses
or all monitored followers are found to be ready.
Master/follower wake-up delay.
Parameters 499
Def / Type
FbEq 16b / 32b
1 = 1
60.0 s / uint16
10 = 1 s / 10 = 1 s