ABB ACS880 Firmware Manual page 185

Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name / Range /
Selection
4.31
Warning word 1
Description
ACS800-compatible warning (alarm) word 1.
The bit assignments of this word correspond to ALARM
WORD 1 in the ACS800. Parameter
word compatibility
determines whether the
assignments are according to the ACS800 Standard or
ACS800 System control program.
Each may indicate several ACS880 warnings as listed
below.
This parameter is read-only.
ACS800 alarm name
(4.120
=
ACS800
Bit
Standard ctrl
program)
0
START INHIBIT
1
Reserved
2
THERMISTOR
3
MOTOR TEMP
4
ACS800 TEMP
5
ENCODER ERR
6
T MEAS ALM
7
Reserved
8
Reserved
9
Reserved
10
Reserved
11
Reserved
12
COMM MOD-
ULE
13
Reserved
14
EARTH FAULT
15
Reserved
4.120 Fault/Warning
ACS880
events indic-
(4.120
=
ated by this
ACS800 Sys-
bit
tem ctrl pro-
(see
Fault tra-
gram)
cing(page649).
START INHIBIT
A5A0
EM STOP
AFE1,
AFE2
MOTOR TEMP
A491, A497,
M
A498,
A499
MOTOR TEMP
A492
ACS800 TEMP
A2BA, A4A9,
A4B0, A4B1,
A4F6
ENCODER ERR
A797, A7B0,
A7B1,
A7E1
T MEAS CIRC
A490, A5EA,
A782,
A8A0
DIGITAL IO
-
ANALOG IO
-
EXT DIGITAL
-
IO
EXT ANALOG
A6E5, A7AA,
IO
A7AB
CH2 COMM
A7CB,
AF80
LOSS
MPROT
A981
SWITCH
EM STOP DEC
-
EARTH FAULT
A2B3
SAFETY
A983
SWITC
Parameters 185