560 Parameters
No.
Name / Range /
Selection
85.05
Curve frequency 2
0.00 ... 600.00 Hz
85.06
Curve frequency 3
0.00 ... 600.00 Hz
85.07
Curve frequency 4
0.00 ... 600.00 Hz
85.08
Curve frequency 5
0.00 ... 600.00 Hz
85.09
Pump curve scale
coef
0.000 ... 30.000
85.10
Head at 0 flowrate 1
0.00 ... 32000.00
85.11
Flowrate max 1
0.00 ... 32000.00
85.12
Downthrust head 1
0.00 ... 32000.00
85.13
Downthrust flowrate
1
0.00 ... 32000.00
85.14
Upthrust head 1
0.00 ... 32000.00
85.15
Upthrust flowrate 1
0.00 ... 32000.00
85.16
DNT zone 50% Head
1
0.00 ... 32000.00
Description
Defines Q-H pump curve frequency 2.
If there are several Q-H curves available from the pump
manufacturer, then set values for the fastest first.
Curve frequency in Hz.
Defines Q-H pump curve frequency 3.
If there are several Q-H curves available from the pump
manufacturer, then set values for the fastest first.
Curve frequency in Hz.
Defines Q-H pump curve frequency 4.
If there are several Q-H curves available from the pump
manufacturer, then set values for the fastest first.
Curve frequency in Hz.
Defines Q-H pump curve frequency 5.
If there are several Q-H curves available from the pump
manufacturer, then set values for the fastest first.
Curve frequency in Hz.
Defines scale coefficient for the Q-H pump curves.
Typically, the pump manufacturers specify Q-H curves
valid for water. Set the value corresponding to a
specific gravity of the pumped fluid.
Pump curve scale coef.
Defines curve 1 maximum Head value at the
corresponding Flow value of 0.
Head at 0 flowrate 1.
Defines curve 1 maximum Flow value at the
corresponding Head value of 0.
Maximum flowrate.
Defines curve 1 Head value for the Downthrust limit.
Downthrust head 1.
Defines curve 1 Flow value for the Downthrust limit.
Downthrust flowrate 1.
Defines curve 1 Head value for the Upthrust limit.
Upthrust head 1.
Defines curve 1 Flow value for the Upthrust limit.
Upthrust flowrate.
Defines curve 1 Head value at the corresponding Flow
value of 1/2 of the Downthrust zone, i.e. Head point at
1/2 of Flow interval 0 and parameter
flowrate
1.
DNT zone 50% head 1.
Def / Type
FbEq 16b / 32b
0.00 Hz / real32
10 = 1 Hz / 100 = 1 Hz
0.00 Hz / real32
10 = 1 Hz / 100 = 1 Hz
0.00 Hz / real32
10 = 1 Hz / 100 = 1 Hz
0.00 Hz / real32
10 = 1 Hz / 100 = 1 Hz
1.000 / real32
1000 = 1 / 1000 = 1
0.00 / real32
10 = 1 / 100 = 1
0.00 / real32
10 = 1 / 100 = 1
0.00 / real32
10 = 1 / 100 = 1
0.00 / real32
10 = 1 / 100 = 1
0.00 / real32
10 = 1 / 100 = 1
0.00 / real32
10 = 1 / 100 = 1
0.00 / real32
85.13 Downthrust
10 = 1 / 100 = 1