360 Parameters
No.
Name / Range /
Selection
30.13
Minimum frequency
-598.00 ... 598.00 Hz
30.14
Maximum frequency
-598.00 ... 598.00 Hz
30.15
Maximum start
current enable
Disable
Enable
30.16
Maximum start
current
0.00 ... 30000.00 A
30.17
Maximum current
0.00 ... 30000.00 A
Description
Defines the minimum allowed frequency.
WARNING!
This value must not be higher than
Maximum
frequency.
WARNING!
This limit is effective in frequency control mode
only.
Minimum frequency. For scaling, see parameter 46.2.
Defines the maximum allowed frequency.
WARNING!
This value must not be lower than
Minimum
frequency.
WARNING!
This limit is effective in frequency control mode
only.
Maximum frequency. For scaling, see parameter 46.2.
A temporary motor current limit specifically for starting
can be defined by this parameter and
start
current.
When this parameter is set to Enable, the drive observes
the start current limit defined by
current. The limit is in force for 2 seconds after initial
magnetization (of an asynchronous induction motor)
or autophasing (of a permanent magnet motor), but
not more often than once in every 7 seconds. Otherwise,
the limit defined by
30.17 Maximum current
Note: The availability of a start current higher than the
general limit depends on drive hardware. See the rating
data in the hardware manual of the drive.
Start current limit disabled.
Start current limit enabled.
Defines a maximum start current when enabled by
parameter
30.15 Maximum start current
Maximum start current.
Defines the maximum allowed motor current.
Maximum motor current.
30.14
30.13
30.16 Maximum
30.16 Maximum start
is in force.
enable.
Def / Type
FbEq 16b / 32b
-50.00; -60.00 (95.20
b0) Hz / real32
- / -
50.00; 60.00 (95.20
b0) Hz / real32
- / -
Disable / uint16
0
1
0.00 A / real32
1 = 1 A / 1 = 1 A
0.00 A / real32
1 = 1 A / 1 = 1 A