ABB ACS880 Firmware Manual page 663

Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

Code
Event name /
(hex)
Aux. code
6481
Task overload
6487
Stack
overflow
64A1
Internal file
load
64A2
Internal
record load
64A3
Application
loading
8006
8007
8008
8009
800A
64A5
Licensing
fault
64A6
Adaptive
program
000A
000C
Cause
Internal fault.
Internal fault.
File read error.
Internal record load error.
Application file incompatible or
corrupted.
Not enough memory for the
application.
The application contains the wrong
system library version.
The application is empty.
The application contains invalid
tasks.
The application contains an
unknown target (system) library
function.
Running the control program is
prevented either because a restrictive
license exists, or because a required
license is missing.
Error running the adaptive program.
Program corrupted or block
non-existent.
Required block input missing.
Fault tracing 663
What to do
Reboot the control unit (using
parameter
96.8 Control board
or by cycling power. If the problem
persists, contact your local ABB
representative.
Reboot the control unit (using
parameter
96.8 Control board
or by cycling power. If the problem
persists, contact your local ABB
representative.
Reboot the control unit (using
parameter
96.8 Control board
or by cycling power. If the problem
persists, contact your local ABB
representative.
Contact your local ABB representative.
Check the auxiliary code. See actions
for each code below.
Reduce the size of the application.
Reduce the number of parameter
mappings.
See the drive-specific log generated
by Automation Builder.
Update the system library or
reinstall Automation Builder.
See the drive-specific log generated
by Automation Builder.
In Automation Builder, give a "Clean"
command and reload the
application.
In Automation Builder, check
application task configuration, give
a "Clean all" command, and reload
the application.
Update the system library or
reinstall Automation Builder.
See the drive-specific log generated
by Automation Builder.
Record the auxiliary codes of all active
licensing faults and contact your
product vendor for further
instructions.
Check the auxiliary code (format XXXX
YYYY). "XXXX" specifies the number
of the function block (0000 = generic
error). "YYYY" indicates the problem
(see actions for each code below).
Restore the template program or
download the program to the drive.
Check the inputs of the block.
boot)
boot)
boot)