608 Parameters
No.
Name / Range /
Selection
b3
Reserved
b4
Torque unit
b5...15
Reserved
0000h...FFFFh
96.20
Time sync primary
source
Internal
DDCS Controller
Fieldbus A or B
Fieldbus A
Fieldbus B
D2D or M/F
Embedded FB
Panel link
Ethernet tool link
96.23
M/F and D2D clock
synchronization
Inactive
Active
96.24
Full days since 1st
Jan 1980
1...59999 days
96.25
Time in minutes
within 24 h
0...1439 min
96.26
Time in ms within
one minute
0...59999 ms
96.29
Time sync source
status
Description
0 = Nm (N·m)
1 = lbft (lbf·ft)
Defines the 1st priority external source for
synchronization of the drive's time and date.
The date and time can also be directly set into
96.24
...
96.26
in which case this parameter is ignored.
No external source selected.
External controller.
Fieldbus interface A or B.
Fieldbus interface A.
Fieldbus interface B.
The master station on a master/follower or
drive-to-drive link.
Embedded fieldbus interface.
Control panel, or Drive Composer PC tool connected
to the control panel.
Drive Composer PC tool through an FENA module.
In the master drive, activates clock synchronization for
master/follower and drive-to-drive communication.
Clock synchronization not active.
Clock synchronization active.
Number of full days passed since beginning of the year
1980. This parameter, together with
minutes within 24 h
and
minute
makes it possible to set the date and time in
the drive via the parameter interface from a fieldbus
or application program. This may be necessary if the
fieldbus protocol does not support time
synchronization.
Days count. 1 = 1st January 1980.
Number of full minutes passed since midnight. For
example, the value 860 corresponds to 2:20 pm.
See parameter
96.24 Full days since 1st Jan
Minutes since midnight.
Number of milliseconds passed since last minute.
See parameter
96.24 Full days since 1st Jan
Number of milliseconds since last minute.
Time source status word.
Note: This parameter is read-only.
96.25 Time in
96.26 Time in ms within one
1980.
1980.
Def / Type
FbEq 16b / 32b
1 = 1
DDCS Controller /
uint16
0
1
2
3
4
5
6
8
9
Inactive / uint16
0
1
- days / uint16
1 = 1 days / 1 = 1 days
0 min / uint16
1 = 1 min / 1 = 1 min
0 ms / uint16
1 = 1 ms / 1 = 1 ms
- / uint16