ABB ACS880 Firmware Manual page 535

Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name / Range /
Selection
76.80
PI feedback %
-300.00 ... 300.00%
76.81
PI setpoint %
-300.00 ... 300.00%
76.82
PI error %
-300.00 ... 300.00%
76.83
P term
-300.00 ... 300.00%
76.84
I term
-300.00 ... 300.00%
76.85
PI output
-300.00 ... 300.00%
76.86
Process 1 feedback
signal
-30000.00 ...
30000.00
76.87
Process 2 feedback
signal
-30000.00 ...
30000.00
76.99
Auto mode status
word
b0
Auto mode off
b1
Process 1 ctrl mode
b2
Process 2 ctrl mode
b3...7
Reserved
b8
PI output max limit
b9
PI output min limit
Description
Displays the process control feedback signal value used
for the PI controller.
This parameter is read-only.
PI feedback.
Displays the process control set point reference signal
ramped value used for the PI control.
This parameter is read-only.
PI setpoint.
Displays the process control error which is effectively
the difference between ramped set point reference
and process feedback signal.
This parameter is read-only.
PI error.
Displays the content of the PI output P-term
component.
This parameter is read-only.
P term.
Displays the content of the PI output I-term component.
This parameter is read-only.
I term.
Displays the output of the PI controller in % of the
speed range defined for the automatic process control.
This parameter is read-only.
PI output.
Displays the actual value of the feedback signal selected
for process 1.
This parameter is read-only.
Process 1 feedback signal.
Displays the actual value of the feedback signal selected
for process 2.
This parameter is read-only.
Process 2 feedback signal.
Displays the status word of the functions controlling
ESP control program starting routines, i.e. Starting
speed, Acceleration assistance, Kick-start and Current
pulse-start.
No auto mode process control is active.
Auto mode Process 1 closed loop control is active.
Auto mode Process 2 closed loop control is active.
PI output is at maximum limit.
PI output is at minimum limit.
Parameters 535
Def / Type
FbEq 16b / 32b
0.00% / real32
10 = 1% / 100 = 1%
0.00% / real32
10 = 1% / 100 = 1%
0.00% / real32
10 = 1% / 100 = 1%
0.00% / real32
10 = 1% / 100 = 1%
0.00% / real32
10 = 1% / 100 = 1%
0.00% / real32
10 = 1% / 100 = 1%
0.00 / real32
10 = 1 / 100 = 1
0.00 / real32
10 = 1 / 100 = 1
- / unit16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents