No.
Name / Range /
Selection
b0
Time tick received
b1
Aux Time tick
received
b2
Tick interval is too
long
b3
DDCS controller
b4
Master/Follower
b5
Reserved
b6
D2D
b7
FbusA
b8
FbusB
b9
EFB
b10
Reserved
b11
Panel link
b12
Ethernet tool link
b13
Parameter setting
b14
RTC
b15
Drive On-Time
0000h...FFFFh
96.31
Drive ID number
0...32767
96.39
Power up event
logging
Disable
Enable
96.51
Clear fault and event
logger
Description
1 = 1st priority tick received: Tick has been received
from 1st priority source (or from
1 = 2nd priority tick received: Tick has been received
from 2nd priority source.
1 = Yes: Tick interval too long (accuracy compromised).
1 = Tick received: Tick has been received from an
external controller.
1 = Tick received: Tick has been received through the
master/follower link.
1 = Tick received: Tick has been received through the
drive-to-drive link.
1 = Tick received: Tick has been received through
fieldbus interface A.
1 = Tick received: Tick has been received through
fieldbus interface B.
1 = Tick received: Tick has been received through the
embedded fieldbus interface.
1 = Tick received: Tick has been received from the
control panel, or Drive Composer PC tool connected to
the control panel.
1 = Tick received: Tick has been received from Drive
Composer PC tool through an FENA module.
1 = Tick received: Tick has been set by parameters
96.24
... 96.26.
1 = RTC time in use: Time and date have been read from
the real-time clock.
1 = Drive on-time in use: Time and date are displaying
drive on-time.
Specifies an ID number for the drive. The ID can be read
by an external controller through DDCS, for example,
for comparison with an ID contained by the controller's
application.
ID number.
Enables/disables power-up logging. When enabled, an
event
(B5A2 Power
up) is logged by the drive upon each
power-up.
Power-up event logging disabled.
Power-up event logging enabled.
Clears the contents of the event logs. See section
Warning/fault history and analysis (page
Parameters 609
96.24
... 96.26).
650).
Def / Type
FbEq 16b / 32b
1 = 1
0 / uint16
1 = 1 / 1 = 1
Enable / uint16
0
1
- / uint16

Hide quick links:

Advertisement

Table of Contents
loading