ABB ACS880 Firmware Manual page 506

Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

506 Parameters
No.
Name / Range /
Selection
Follower CW B6 high
Other [value]
61.2
M/F data 2 selection
61.3
M/F data 3 selection
61.25
M/F data 1 value
0...65535
61.26
M/F data 2 value
0...65535
61.27
M/F data 3 value
0...65535
Description
Scaled velocity value as displayed by 88.54 D2D velocity
send.
Note: Occasionally, below data are also sent to the
follower:
32768-Position initialization or position send type
changed.
32767-Latch 1 triggered in master.
See
Terms and abbreviations (page
Preselects the data to be sent as word 2 onto the
master/follower link.
See also parameter
61.26 M/F data 2
For the selections, see parameter
selection.
Preselects the data to be sent as word 3 onto the
master/follower link.
See also parameter
61.27 M/F data 3
For the selections, see parameter
selection.
Displays the data to be sent onto the master/follower
link as word 1 as an integer.
If no data has been preselected by
selection, the value to be sent can be written directly
into this parameter.
Data to be sent as word 1 in master/follower
communication.
Displays the data to be sent onto the master/follower
link as word 2 as an integer.
If no data has been preselected by
selection, the value to be sent can be written directly
into this parameter.
Data to be sent as word 2 in master/follower
communication.
Displays the data to be sent onto the master/follower
link as word 3 as an integer.
If no data has been preselected by
selection, the value to be sent can be written directly
into this parameter.
Data to be sent as word 3 in master/follower
communication.
Def / Type
FbEq 16b / 32b
22582
169).
Used speed reference
/ uint32
value.
61.1 M/F data 1
Torque reference act
5 / uint32
value.
61.1 M/F data 1
- / uint16
61.1 M/F data 1
- / -
- / uint16
61.2 M/F data 2
- / -
- / uint16
61.3 M/F data 3
- / -

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents