ABB ACS880 Firmware Manual page 623

Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name / Range /
Selection
99.10
Motor nominal
power
0...30000 kW or hp
99.11
Motor nominal cos
φ
0.00 ... 1.00
99.12
Motor nominal
torque
0.000 ...
4000000.000 Nm or
lb·ft
Description
Defines the nominal motor power. The setting must
match the value on the rating plate of the motor. If
nominal power is not shown on the rating plate,
nominal torque can be entered instead in parameter
99.12.
If multiple motors are connected to the drive, enter the
total power of the motors.
The unit is selected by parameter
Note: This parameter cannot be changed while the
drive is running.
Nominal power of the motor.
Defines the cosphi of the motor for a more accurate
motor model. The value is not obligatory, but is useful
with an asynchronous motor, especially when
performing a standstill identification run. With a
permanent magnet or synchronous reluctance motor,
this value is not needed.
Note: Do not enter an estimated value. If you do not
know the exact value, leave the parameter at zero.
Note: This parameter cannot be changed while the
drive is running.
Cosphi of the motor.
Defines the nominal motor shaft torque. This value can
be given instead of nominal power (99.10) if shown on
the rating plate of the motor.
The unit is selected by parameter
Note: This setting is an alternative to the nominal
power value (99.10). If both are entered,
priority.
Note: This parameter cannot be changed while the
drive is running.
Nominal motor torque.
Parameters 623
Def / Type
FbEq 16b / 32b
- / real32
96.16 Unit
selection.
1 = 1 kW or hp / 100 =
1 kW or hp
0.00 / real32
100 = 1 / 100 = 1
0.000 Nm or lb·ft /
uint32
96.16 Unit
selection.
99.12
takes
1 = 1 Nm or lb·ft /
1000 = 1 Nm or lb·ft

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents