350 Parameters
No.
Name / Range /
Selection
28.22
Constant frequency
sel1
Not selected
Selected
DI1
DI2
DI3
DI4
DI5
DI6
DIO1
DIO2
Other [bit]
Description
When bit 0 of parameter
function
is 0 (Separate), selects a source that activates
constant frequency 1.
When bit 0 of parameter
function
is 1 (Packed), this parameter and parameters
28.23 Constant frequency sel2
frequency sel3
select three sources whose states
activate constant frequencies as follows:
Source
Source
defined by
defined by
par.
28.22
par.
28.23
0
0
1
0
0
1
1
1
0
0
1
0
0
1
1
1
0
1
Digital input DI1
(10.2 DI delayed
Digital input DI2
(10.2 DI delayed
Digital input DI3
(10.2 DI delayed
Digital input DI4
(10.2 DI delayed
Digital input DI5
(10.2 DI delayed
Digital input DI6
(10.2 DI delayed
Digital input/output DIO1
0).
Digital input/output DIO2
1).
See
Terms and abbreviations (page
28.21 Constant frequency
28.21 Constant frequency
and
28.24 Constant
Source
Constant fre-
defined by
quency active
par.
28.24
0
None
0
Constant fre-
quency 1
0
Constant fre-
quency 2
0
Constant fre-
quency 3
1
Constant fre-
quency 4
1
Constant fre-
quency 5
1
Constant fre-
quency 6
1
Constant fre-
quency 7
status, bit 0).
status, bit 1).
status, bit 2).
status, bit 3).
status, bit 4).
status, bit 5).
(11.2 DIO delayed
status, bit
(11.2 DIO delayed
status, bit
169).
Def / Type
FbEq 16b / 32b
Not selected / uint32
0
1
2
3
4
5
6
7
10
11