620 Parameters
No.
Name / Range /
Selection
0.00 ... 100000.00
mH
98.13
Ld user SI
0.00 ... 100000.00
mH
98.14
Lq user SI
0.00 ... 100000.00
mH
98.15
Position offset user
0.0 ... 360.0 deg
Description
Leakage inductance.
Defines the direct axis (synchronous) inductance.
Note: This parameter is valid only for permanent
magnet motors.
Direct axis inductance.
Defines the quadrature axis (synchronous) inductance.
Note: This parameter is valid only for permanent
magnet motors.
Quadrature axis inductance.
Defines an angle offset between the zero position of
the synchronous motor and the zero position of the
position sensor.
This value is initially set by the autophasing routine
when an absolute encoder or an incremental encoder
with Z-pulse is used. The value can be fine-tuned by
setting
98.1 User motor model mode
or
Motor parameters & position
Note: The value is in electrical degrees. The electrical
angle equals the mechanical angle multiplied by the
number of motor pole pairs.
Note: This parameter is valid only for permanent
magnet motors.
Angle offset.
to
Position offset
offset.
Def / Type
FbEq 16b / 32b
10 = 1 mH / 100 mH
0.00 mH / real32
10 = 1 mH / 100 mH
0.00 mH / real32
10 = 1 mH / 100 mH
0.0 deg / real32
1 = 1 deg / 1 = 1 deg