ABB ACS880 Firmware Manual page 523

Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name / Range /
Selection
ESP CW bit 15
Other [bit]
74.51
On time
0.0 ... 90000.0 min
74.52
Off time
0.0 ... 90000.0 min
74.79
Fly-start speed
check
Not selected
Selected
DI1
DI2
DI3
DI4
DI5
DI6
DIO1
DIO2
Other [bit]
74.80
Observer speed
measured
0.00 ... 598.00 Hz
74.99
ESP start/stop sw
Description
Parameter
74.1 ESP control word (page
controls enable/disable status of the function.
See
Terms and abbreviations (page
Defines the time for the motor to stay ON.
After the ON cycle is over, drive will automatically shut
down and switch to
74.52 Off time
On time.
Defines the time for the motor to stay OFF.
After the OFF cycle is over, drive will automatically shut
down and switch to
74.51 On time
Off time.
Defines the source for the Fly start check enable signal.
The function will check the actual motor speed before
making decision on starting procedure.
If the speed is outside safe-to-restart speed region,
then the control program logic will skip starting
routines and get in to production state from the current
motor speed.
Note: This parameter setting has no effect in case
parameter
74.30 Speed observer enable
the Fly-start speed check employs backspin observer
function to check the speed. Also, by activating this
parameter will delay normal start of the drive for the
time necessary to perform measurement defined in
parameter
74.39 Measurement
Flying start check function is disabled.
Flying start check function is enabled.
Digital input DI1
(10.2 DI delayed
Digital input DI2
(10.2 DI delayed
Digital input DI3
(10.2 DI delayed
Digital input DI4
(10.2 DI delayed
Digital input DI5
(10.2 DI delayed
Digital input DI6
(10.2 DI delayed
Digital input/output DIO1
0).
Digital input/output DIO2
1).
See
Terms and abbreviations (page
Displays the speed measured by the Backspin Speed
Observer function.
This parameter is read-only.
Observer speed measured.
Displays status word of the functions controlling ESP
specific start/stop logic.
519), bit 15 status
169).
counter.
counter.
is ON. Since
delay.
status, bit 0).
status, bit 1).
status, bit 2).
status, bit 3).
status, bit 4).
status, bit 5).
(11.2 DIO delayed
status, bit
(11.2 DIO delayed
status, bit
169).
Parameters 523
Def / Type
FbEq 16b / 32b
12
0.0 min / real32
1 = 1 min / 10 = 1 min
0.00 min / real32
1 = 1 min / 10 = 1 min
Not selected / unit32
0
1
2
3
4
5
6
7
10
11
0.00 Hz / real32
100 = 1 Hz / 10 = 1 Hz
- / unit16