628 Parameters
No.
Name / Range /
Selection
99.15
Motor polepairs
calculated
0...1000
99.16
Motor phase order
U V W
U W V
99.18
Sine filter
inductance
0.000 ... 100000.000
mH
Description
Calculated number of pole pairs in the motor.
This parameter is read-only.
Number of pole pairs.
Switches the rotation direction of the motor. This
parameter can be used if the motor turns in the wrong
direction (for example, because of the wrong phase
order in the motor cable), and correcting the cabling
is considered impractical.
Note: Changing this parameter does not affect speed
reference polarities, so positive speed reference will
rotate the motor forward. The phase order selection
just ensures that "forward" is in fact the correct
direction.
Note: After changing this parameter, the sign of
encoder feedback (if any) must be checked. This can
be done by setting parameter
selection
to Estimate, and comparing the sign of
Motor speed for control
90.20 Encoder 2
speed). If the sign of the measurement
is incorrect, the encoder wiring must be corrected or
the sign of
90.43 Motor gear numerator
Note: This parameter cannot be changed while the
drive is running.
Normal.
Reversed rotation direction.
Defines the inductance of a custom sine filter, i.e. when
parameter
95.15 Special HW settings
Note: For an ABB sine filter
bit 1), this parameter is set automatically and should
not be adjusted.
Inductance of custom sine filter.
90.41 Motor feedback
to
90.10 Encoder 1 speed
reversed.
bit 3 is activated.
(95.15 Special HW settings
Def / Type
FbEq 16b / 32b
0 / uint16
1 = 1 / 1 = 1
U V W / uint16
90.1
(or
0
1
0.000 mH / real32
1000 = 1 mH / 1000 =
1 mH