548 Parameters
No.
Name / Range /
Selection
-100.00 ... 100.00%
80.26
Additive value 6
-100.00 ... 100.00%
80.27
Additive value 7
-100.00 ... 100.00%
80.28
Additive value 8
-100.00 ... 100.00%
80.31
Validate tuning cmd
Not selected
Selected
DI1
DI2
DI3
DI4
DI5
DI6
DIO1
DIO2
Other [bit]
80.32
Voltage tuner source
NULL
AI1 scaled
AI2 scaled
FB A ref1
FB A ref2
EFB ref1
Description
Additive value 5.
Defines additive point 6 in the custom user U/F curve.
Additive value 6.
Defines additive point 7 in the custom user U/F curve.
Additive value 7.
Defines additive point 8 in the custom user U/F curve.
Additive value 8.
Defines the source for U/F curve tuning command.
This parameter provides possibility to manually tune
the U/F curve point settings while motor is running.
When this parameter is activated, the value received
from parameter
80.32 Voltage tuner source
the voltage additive. It is converted to motor flux
reference and applied instantly instead of the value set
in the u/f curve.
After tuning command is disabled, the actual motor
speed frequency is automatically written to the nearest
frequency point in the U/F curve and the voltage
correction used at that moment is then written to
corresponding Additive voltage parameter setting.
Validate tuning cmd is not selected.
Validate tuning cmd is selected.
Digital input DI1
(10.2 DI delayed
Digital input DI2
(10.2 DI delayed
Digital input DI3
(10.2 DI delayed
Digital input DI4
(10.2 DI delayed
Digital input DI5
(10.2 DI delayed
Digital input DI6
(10.2 DI delayed
Digital input/output DIO1
0).
Digital input/output DIO2
1).
See
Terms and abbreviations (page
Defines the source for the voltage tuner signal.
This is used as additive voltage when parameter
Validate tuning cmd
is active.
Zero
12.12 AI1 scaled value (page
12.22 AI2 scaled value (page
3.5 FB A reference 1 (page
3.6 FB A reference 2 (page
3.9 EFB reference 1 (page
is taken as
status, bit 0).
status, bit 1).
status, bit 2).
status, bit 3).
status, bit 4).
status, bit 5).
(11.2 DIO delayed
status, bit
(11.2 DIO delayed
status, bit
169).
226).
228).
179).
179).
179).
Def / Type
FbEq 16b / 32b
10 = 1% / 100 = 1%
0.00% / real32
10 = 1% / 100 = 1%
0.00% / real32
10 = 1% / 100 = 1%
0.00% / real32
10 = 1% / 100 = 1%
Not selected / unit32
0
1
2
3
4
5
6
7
10
11
NULL / unit32
80.31
0
1
2
3
4
5