ABB ACS880 Firmware Manual page 507

Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name / Range /
Selection
61.45
Data set 2 data 1
selection
None
CW 16bit
SW 16bit
Act1 16bit
Act2 16bit
Other [value]
61.46
Data set 2 data 2
selection
61.47
Data set 2 data 3
selection
...
...
61.50
Data set 4 data 3
selection
61.51
Data set 11 data 1
selection
None
CW 16bit
SW 16bit
Act1 16bit
Act2 16bit
Other [value]
Description
Parameters
61.45...61.50
data sets 2 and 4 to the external controller. These data
sets are used in ModuleBus communication with a
"standard drive"
(60.50 DDCS controller drive type
ABB standard
drive). Parameters
the data to be sent to the external controller. If no data
has been preselected, the value to be sent can be
written directly into these parameters. For example,
this parameter preselects the data for word 1 of data
set 2. Parameter
61.95 Data set 2 data 1 value
the selected data in integer format. If no data is
preselected, the value to be sent can be written directly
into parameter 61.95.
None.
Control Word (16 bits)
Status Word (16 bits)
Actual value ACT1 (16 bits)
Actual value ACT2 (16 bits)
See
Terms and abbreviations (page
Preselects the data to be sent as word 2 of data set 2
to the external controller.
See also parameter
61.96 Data set 2 data 2
For the selections, see parameter
1
selection.
See parameter
61.45 Data set 2 data 1
...
See parameter
61.45 Data set 2 data 1
Parameters
61.51...61.74
data sets 11, 13, 15, 17, 19, 21, 23 and 25 to the external
controller.
Parameters
61.101...61.124
to the external controller. If no data has been
preselected, the value to be sent can be written directly
into these parameters.
For example, this parameter preselects the data for
word 1 of data set 11. Parameter
1 value
displays the selected data in integer format. If
no data is preselected, the value to be sent can be
written directly into parameter 61.101.
None.
Control Word (16 bits)
Status Word (16 bits)
Actual value ACT1 (16 bits)
Actual value ACT2 (16 bits)
See
Terms and abbreviations (page
preselect data to be sent in
61.95...61.100
display
displays
169).
value.
61.45 Data set 2 data
selection.
selection.
preselect data to be sent in
display the data to be sent
61.101 Data set 11 data
169).
Parameters 507
Def / Type
FbEq 16b / 32b
None / uint32
=
0
1
4
5
6
None / uint32
None / uint32
...
None / uint32
None / uint32
0
1
4
5
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents