ABB ACS880 Firmware Manual page 692

Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

692 Fault tracing
Code
Event name /
(hex)
Aux. code
D105
Signal
supervision 3
D106
Signal
supervision 3
D113
Out of sync
D200
Cleaning max
warning
D20B
Signal
supervision 3
D20C
Signal
supervision 3
D20D
Signal
supervision 3
D20E
Signal
supervision 3
D213
Out of sync
FA81
Safe torque
off 1 loss
Cause
Fault generated by the signal
supervision 6 function.
Fault generated by the signal
supervision 7 function.
One or more of the sync loss
conditions is fulfilled.
Maximum number of cleaning in the
defined time frame has been
exceeded.
Warning generated by the signal
supervision 4 function.
Warning generated by the signal
supervision 5 function.
Warning generated by the signal
supervision 6 function.
Warning generated by the signal
supervision 7 function.
One or more of the sync loss
conditions is fulfilled.
Safe torque off function is active, ie.
STO circuit 1 is broken.
What to do
Check the source of the fault
(parameter
32.217 Supervision 5
signal).
Check the source of the fault
(parameter
32.237 Supervision 7
signal).
Check the following parameters:
31.203 Sync loss sample period
31.204 Sync loss cos phi filter
time
31.205 Sync loss cos phi drop
31.206 Sync loss cos phi minimum
level
Check motor and motor cables.
Check parameters
81.51 Cleaning max
event
to
81.53 Clean max period
clean maximum protection settings.
Check the source of the warning
(parameter
32.207 Supervision 4
signal).
Check the source of the warning
(parameter
32.217 Supervision 5
signal).
Check the source of the warning
(parameter
32.227 Supervision 6
signal).
Check the source of the warning
(parameter
32.237 Supervision 7
signal).
Check the following parameters:
31.203 Sync loss sample period
31.204 Sync loss cos phi filter
time
31.205 Sync loss cos phi drop
31.206 Sync loss cos phi minimum
level
Check safety circuit connections. For
more information, see appropriate
drive hardware manual and
description of parameter
indication run/stop (page
Check the auxiliary code, The code
contains location information,
especially with parallel-connected
inverter modules.
for
31.22 STO
370).